FEATURES & BENEFITS
- Provides control of sample temperature up to +300°C
- Programmable Controller offers single set point or up to 10 programmable set points. Temperature ramping between set points is possible if used with RheocalcT Software
Note: Requires optional cable HT-106 when QC control with RheocalcT is implemented.
- Compatible with standard Brookfield Viscometers and DV3T Rheometers
Note: requires optional cable DVP-141 when controlled by DV3T Rheometer
- Supplied with reusable stainless steel sample container and five disposable aluminum sample chambers
- Outputs: 0-4 Vdc for chart recorder; RS-232 for use with DV3T and/or RheocalcT
DISPOSABLE SPINDLE/CHAMBERS OPTION
Disposable sample chamber with Disposable Spindle SC4-27D* is ideal for asphalts or any difficult-to-clean material. Requires special adapter (SC4-DSY).
*Optional SC4-27D is available in quantities of 100, (SC4-27D-100)
What's Included
Choice of one SC4 Spindle*
Alignment Bracket
Thermo Container with safety guard and insulating cap
One Removable Sample Chamber
Five Disposable Sample Chambers
Extracting Tools
Temperature Controller with an RTD probe
*Specify when ordering.
SPECIFICATIONS
Thermosel Adapter Viscosity Ranges cP (mPa·s) |
SPINDLE
SAMPLE VOLUME
SHEAR RATE
(SEC-1) † MODEL |
SC4-18 8mL 1.32N |
SC4-31 10mL .34N |
SC4-34 9.5mL .28N |
SC4-21 8mL .93N |
SC4-27* 10.5mL .34N |
LVDV3T |
1.2-30K |
12-300K |
24-600K |
Not applicable for historical |
LVDV2T |
1.5-30K |
15-300K |
30-600K |
reasons. However, it is possible |
DV1MLV |
3-10K |
30-100K |
60-200K |
to use the above spindles |
LVDVE |
3-10K |
30-100K |
60-200K |
with any of these instruments. |
LVT |
5-10K |
50-100K |
100-200K |
Digital Viscometers/Rheometers |
RVDV3T |
|
|
|
20-500K |
100-2.5M |
RVDV2T |
|
|
|
25-500K |
125-2.5M |
DV1MRV |
|
|
|
50-170K |
250-830K |
RVDVE |
|
50-170K |
250-830K |
RVT |
will automatically calculate |
50-100K |
250-500K |
HADV3T |
viscosity. Please contact |
40-1M |
200-5M |
HADV2T |
Brookfield or an authorized |
50-1M |
250-5M |
DV1MHA |
dealer if you require |
100-300K |
500-1.7M |
HADVE |
Information on viscosity range. |
100-300K |
500-1.7M |
HAT |
|
|
|
100-200K |
500-1M |
HBDV3T |
|
|
|
160-M |
800-20M |
HBDV2T |
|
|
|
200-4M |
1K-20M |
DV1MHB |
|
|
|
400-1.3M |
2K-6.7M |
HBDVE |
|
|
|
400-1.3M |
2K-6.7M |
HBT |
|
|
|
400-800K |
2K-4M |
Thermosel Adapter Viscosity Ranges cP (mPa·s) |
SPINDLE
SAMPLE VOLUME
SHEAR RATE (SEC-1) †
MODEL |
SC4-28
11.5mL
.28N |
SC4-29
13mL
.25N |
HT-DIN-81**
7mL
1.29N |
LVDV3T |
|
1.0-10K |
LVDV2T |
Not applicable for historical reasons. |
3.4-10K |
DV1MLV |
See note above. |
3.4-10K |
LVDVE |
|
N/A |
LVT |
|
5.7-10K |
RVDV3T |
200-5M |
400-10M |
14.6-10K |
RVDV2T |
250-5M |
500-10M |
36.5-10K |
DV1MRV |
500-1.7M |
1K-3.3M |
36.5-10K |
RVDVE |
500-1.7M |
1K-3.3M |
N/A |
RVT |
500-1M |
1K-2M |
36.5-10K |
HADV3T |
400-10M |
800-20M |
29.2-10K |
HADV2T |
500-10M |
1K-20M |
73.0-10K |
DV1MHA |
1K-3.3M |
2K-6.7M |
73.0-10K |
HADVE |
1K-3.3M |
2K-6.7M |
N/A |
HAT |
1K-2M |
2K-4M |
73.0-10K |
HBDV3T |
1.6K-40M |
3.2K-80M |
116.8-10K |
HBDV2T |
2K-40M |
4K-80M |
292.0-10K |
DV1MHB |
4K-13.3M |
8K-26.7M |
292.0-10K |
HBDVE |
4K-13.3M |
8K-26.7M |
N/A |
HBT |
4K-8M |
8K-16M |
292.0-10K |
M=1 million K=1 thousand N=RPM cP=centipoise mPa·s=Millipascal·seconds
† Spindle SC4-18 1.32×10(rpm)=13.2 sec-1
*Optional disposable SC4-27D spindle is available in quantities of 100, Part No. SC4-27D-100. Requires special chuck/closer, Part No. SC4-DSY, for attachment to viscometer.
**The 81 spindle, Part No. HT-DIN-81, works in an HT-2 or HT-2DB chamber.